Geomembrane hydrostatic pressure tester schematic and installation method - Database & Sql Blog Articles

TP-IP4220CZ6 5V 0.35PF breakdown voltage 6V SOT
Probe current voltage pin 420*4450 head diameter 5.0 over current current and voltage pin
Shunuo varistor / ESD varistor / product complete / Sunlord first-class agent

Geomembrane resistant hydrostatic pressure tester schematic and installation method

Geomembrane hydrostatic pressure tester

1.

Fastening screw

2.

Upper platen

3.

Sealing ring

4.

High pressure tank chassis

5.

Steel mesh

6.

Specimen

7.

Pressurized inlet valve

8.

High pressure tank drain valve

9.

Pressure Sensor

10.

System drain valve

11.

pressure tank

12.

High-pressure pump

13.

Water bucket

Geomembrane resistant hydrostatic pressure measuring instrument installation method

1

, pressure setting: press the set button "back" after power on

Press the shift key"

>

”

Press the adjustment button again"

+

"with"

--

”Re-adjust the value, adjust it, press the set button “Back” to save it. After adjusting the lower limit value, press the set button to exit. Can be set

1-8

The hourly lower limit rises to

0.1MPa

Time clearing: re-do the experiment and keep pressing "

--

"The key is not released, the time value is displayed first.

10

After the second time is available from

0

When the hour starts, "!" can't be mistakenly pressed.

2

Time review: press

"-"

The key pressure is displayed in hours, the upper limit is minutes, and the lower limit is seconds.

30

Return to the pressure display after a second,

3

, Zero adjustment: If there is no pressure after starting, if it does not return to zero, press once to set zero. Do not press the clear button when there is pressure, and then zero after releasing the pressure.

.

4

, open the water injection cover, add pure water

.

Until the tank is full

.

Start the pressurization and open the pressure regulating valve to allow water to flow into the high pressure chamber chassis to just overflow.

5

Place the sample without wrinkles on the rubber ring in the water collector, overflow excess water to ensure no air bubbles in the clamp; cover the upper pressure plate and evenly clamp the sample.

6

To

10

The highest value of the measured hydrostatic pressure values ​​was taken as the hydrostatic pressure resistance value of the sample.

7

The test results are calculated according to relevant standards.