Features:
* 110~295VAC input
*Built-in active power factor correction function
*Protection function: Short circuit, over temperature(PLM-40)
*Fully sealed insulation plastic shell
*Constant current design (constant current mode)
*No-load loss < 0.5W
*Three-phase analog dimming function (PLM-40)
*Natural cooling
*Class 2 or 1 isolation, no F.G
*IP30 Design
*Class 2 or 1Â power supply, by LPS(limited power source) test
*Low cost, high reliability
*Suitable for indoor LED lighting application
*2 years warranty
Series No. | Model No. | Specification | |||||||||||||
AC input range | AC inrush Current(Max.) | Start time | Short cirduit protection | PLM-40 over temperature protection | Withstand Voltage | Working Temperature | EMC standards | Connector input/output |
Output | Voltage tolerance | Ripple&noise | Efficiency | Size(mm) | ||
PLM-12 | PLM-12-350 | 110~295VAC;156~417VDC | Cold start, 15A/230VAC |
500ms (230VAC full load) | hiccup mode,auto-recovery | / | I/P-O/P:3.75KVAC | -30ºC~+50ºC | EN55015,EN61000-3-2 class C,EN61000-3-3,EN61000-4-2,3,4,5,6,8,11, EN61547 | 2+2P,Layering type terminal type | 22~36V,350mA | ±5% | 3.6V | 85.0% | 145x38x22 |
PLM-12-500 | 15~24V,500mA | ±5% | 2.4V | 84.0% | |||||||||||
PLM-12-700 | 11~18V,700mA | ±5% | 2.4V | 83.0% | |||||||||||
PLM-12-1050 |  | ±5% | 1.8V | 81.0% | |||||||||||
PLM-25 | PLM-25-350 | 110~295VAC;156~417VDC | Cold start, 15A/230VAC |
500ms (230VAC full load) | hiccup mode,auto-recovery | / | I/P-O/P:3.75KVAC | -30ºC~+45ºC | 42~72V,350mA | ±5% | 7.2V | 87.0% | 145x38x22 | ||
PLM-25-500 | 30~50V, 500mA | ±5% | 5.0V | 86.0% | |||||||||||
PLM-25-700 | 21~36V,700mA | ±5% | 3.6V | 86.0% | |||||||||||
PLM-25-1050 | 14~24V,1050mA | ±5% | 2.4V | 85.0% | |||||||||||
PLM-40 | PLM-40-350 | 110~295VAC;156~417VDC | Cold start, 15A/230VAC |
500ms (230VAC full load) | hiccup mode,auto-recovery | hiccup mode,auto-recovery | I/P-O/P:3.75KVAC | -30ºC~+45ºC | 53~105V,350mA | ±5% | 10V | 88.0% | 175x42x24 | ||
PLM-40-500 | 40~80V, 500mA | ±5% | 8.0V | 88.0% | |||||||||||
PLM-40-700 | 29~57V,700mA | ±5% | 6.0V | 87.0% | |||||||||||
PLM-40-1050 | 19~38V,1050mA | ±5% | 4.0V | 87.0% | |||||||||||
PLM-40-1400 | 15~29V,1400mA | ±5% | 3.0V | 86.0% | |||||||||||
PLM-40-1750 | 12~23V,1750mA | ±5% | 2.5V | 86.0% |
Features:
* 110~295VAC input
*Built-in active power factor correction function
*Protection function: Short circuit, over temperature(PLM-40)
*Fully sealed insulation plastic shell
*Constant current design (constant current mode)
*No-load loss < 0.5W
*Three-phase analog dimming function (PLM-40)
*Natural cooling
*Class 2 or 1 isolation, no F.G
*IP30 Design
*Class 2 or 1Â power supply, by LPS(limited power source) test
*Low cost, high reliability
*Suitable for indoor LED lighting application
*2 years warranty
Series No. | Model No. | Specification | |||||||||||||
AC input range | AC inrush Current(Max.) | Start time | Short cirduit protection | PLM-40 over temperature protection | Withstand Voltage | Working Temperature | EMC standards | Connector input/output |
Output | Voltage tolerance | Ripple&noise | Efficiency | Size(mm) | ||
PLM-12 | PLM-12-350 | 110~295VAC;156~417VDC | Cold start, 15A/230VAC |
500ms (230VAC full load) | hiccup mode,auto-recovery | / | I/P-O/P:3.75KVAC | -30ºC~+50ºC | EN55015,EN61000-3-2 class C,EN61000-3-3,EN61000-4-2,3,4,5,6,8,11, EN61547 | 2+2P,Layering type terminal type | 22~36V,350mA | ±5% | 3.6V | 85.0% | 145x38x22 |
PLM-12-500 | 15~24V,500mA | ±5% | 2.4V | 84.0% | |||||||||||
PLM-12-700 | 11~18V,700mA | ±5% | 2.4V | 83.0% | |||||||||||
PLM-12-1050 |  | ±5% | 1.8V | 81.0% | |||||||||||
PLM-25 | PLM-25-350 | 110~295VAC;156~417VDC | Cold start, 15A/230VAC |
500ms (230VAC full load) | hiccup mode,auto-recovery | / | I/P-O/P:3.75KVAC | -30ºC~+45ºC | 42~72V,350mA | ±5% | 7.2V | 87.0% | 145x38x22 | ||
PLM-25-500 | 30~50V, 500mA | ±5% | 5.0V | 86.0% | |||||||||||
PLM-25-700 | 21~36V,700mA | ±5% | 3.6V | 86.0% | |||||||||||
PLM-25-1050 | 14~24V,1050mA | ±5% | 2.4V | 85.0% | |||||||||||
PLM-40 | PLM-40-350 | 110~295VAC;156~417VDC | Cold start, 15A/230VAC |
500ms (230VAC full load) | hiccup mode,auto-recovery | hiccup mode,auto-recovery | I/P-O/P:3.75KVAC | -30ºC~+45ºC | 53~105V,350mA | ±5% | 10V | 88.0% | 175x42x24 | ||
PLM-40-500 | 40~80V, 500mA | ±5% | 8.0V | 88.0% | |||||||||||
PLM-40-700 | 29~57V,700mA | ±5% | 6.0V | 87.0% | |||||||||||
PLM-40-1050 | 19~38V,1050mA | ±5% | 4.0V | 87.0% | |||||||||||
PLM-40-1400 | 15~29V,1400mA | ±5% | 3.0V | 86.0% | |||||||||||
PLM-40-1750 | 12~23V,1750mA | ±5% | 2.5V | 86.0% |
- Multiple USB Charger Extension Socket provide quick charging for your mobile electronic devices.
- Smart Charging: 5V 2.4A/3.4A/4.2A/4.8A/6A Usb Ports Extension Cord support smart charging. Protect your devices from over charging damage.
- Multiple Outlets Power Strip With Usb Ports allowing you to plug in various electronics and electrical devices.
- PC/ABS flame retardant housing, phosphor bronze+pure copper high conductivity Power Strip Usb .
-- Qualified Power Cord Receptacle Extension With Usb allowing you extend the outlet 6 feet (2 meters) away from the wall or even further with long power strip.
Power Strip With Usb
Power Strip With Usb,Power Strip With Usb Ports,Usb Ports Extension Cord,Power Strip Usb,Receptacle Extension With Usb,USB Charger Extension Socket
ZhongShan JITONGLONG Plastic Hardware Co. Ltd. , http://www.toukoo-electronics.com